Publication:
Electrochemical determination of ceftriaxone using polyurethane-modified electrode containing caffeic acid and chitosan

dc.contributor.authorHassinea, Chedia Ben Ali
dc.contributor.authorGüngör, Ö.
dc.contributor.authorBurc, M.
dc.contributor.authorÖzcan, İ.
dc.contributor.authorKöytepe, S.
dc.contributor.authorDuran, S. T.
dc.contributor.ozugradstudentHassinea, Chedia Ben Ali
dc.date.accessioned2022-09-19T13:25:16Z
dc.date.available2022-09-19T13:25:16Z
dc.date.issued2022-04-13
dc.description.abstractThe aim of this work was to develop an electrochemical sensor based on caffeic acid and chitosan-containing polyurethane (CAC-PU) films modified platinum electrode for ceftriaxone (CFX) determination. For this aim, firstly the CAC-PU structures were synthesized from three different diisocyanates and these structures were characterized with spectroscopic, thermal and surface analysis techniques. Then, these CAC-PU structures were coated on bare Pt electrode surface for the preparation of CFX selective sensors. Throughout this study several analytical parameters, such as film thickness, electrolyte type, pH effect, and scan rate were investigated by using differential pulse voltammetry (DPV) method. Under the optimized conditions, the voltammetric test results showed best analytical performances for CFX detection with a linear range from 0.1 to 1.5 mM. Limit of detection (LOD) and correlation coefficient (R-2) were obtained 52 mu M and 0.9991 using CAC-PU modified electrode, respectively. Stability of the modified electrode was found to be 96.78% by using reproducibility experiments (n = 10). Applicable of the presented sensor was tested in two synthetic urine samples and recoveries values were obtained 98.7% and 110%, respectively. The prepared modified electrode exhibits high repeatability, fast response, and high sensitivity, which makes it suitable for the detection of CFX in urine samples.en_US
dc.identifier.doi10.1080/25740881.2021.2005092en_US
dc.identifier.endpage623en_US
dc.identifier.issn2574-0881en_US
dc.identifier.issue6en_US
dc.identifier.scopus2-s2.0-85119885663
dc.identifier.startpage609en_US
dc.identifier.urihttp://hdl.handle.net/10679/7864
dc.identifier.urihttps://doi.org/10.1080/25740881.2021.2005092
dc.identifier.volume61en_US
dc.identifier.wos000722075400001
dc.language.isoengen_US
dc.peerreviewedyesen_US
dc.publicationstatusPublisheden_US
dc.publisherTaylor & Francisen_US
dc.relation.ispartofPolymer-Plastics Technology and Materials
dc.relation.publicationcategoryInternational Refereed Journal
dc.rightsrestrictedAccess
dc.subject.keywordsCeftriaxoneen_US
dc.subject.keywordsPolyurethane membraneen_US
dc.subject.keywordsElectrode modificationen_US
dc.subject.keywordsSensoren_US
dc.subject.keywordsVoltammetryen_US
dc.titleElectrochemical determination of ceftriaxone using polyurethane-modified electrode containing caffeic acid and chitosanen_US
dc.typearticleen_US
dspace.entity.typePublication

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.45 KB
Format:
Item-specific license agreed upon to submission
Description: