<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
An integrated framework for techno-enviro-economic assessment in nanogrids

dc.contributor.authorAhmed, Eihab E. E.
dc.contributor.authorPoyrazoglu, Gokturk
dc.contributor.authorEl Sayed, Ahmad
dc.contributor.departmentElectrical & Electronics Engineering
dc.contributor.ozuauthorPOYRAZOĞLU, Göktürk
dc.contributor.ozugradstudentAhmed, Eihab Elgaily Elmukshfi
dc.contributor.ozugradstudentEl Sayed, Ahmad
dc.date.accessioned2025-06-17T22:14:43Z
dc.date.available2025-06-17T22:14:43.746Z
dc.date.issued2024-03-01
dc.description.abstractThis paper presents an integrated framework designed for capacity planning of grid -connected nanogrid, a small solar and energy storage system that can provide kilowatt -level services to individual buildings. This framework comprehensively evaluates nanogrid cost-effectiveness, sustainability, and reliability, employing a multi -faceted techno-enviro-economic assessment approach. Traditional nanogrid capacity planning often prioritizes peak load requirements, which may lack optimality owing to occasional peak load occurrences. Conversely, optimizing solely for base load requirements might also fall short of effectiveness, compromising reliability and sustainability objectives. The proposed framework employs a threestep, integrated process for nanogrid (NG) capacity planning. Firstly, the Planner module identifies optimal asset sizing considering a two-day lookahead logic. Then, the Operator module serves as a digital twin for the system, conducting hourly calculations over a short-term horizon. Lastly, the Evaluator module evaluates technical, environmental, and economic metrics for each solution, assessing the effectiveness of asset -sizing decisions. A simulated case study has demonstrated the effectiveness of the proposed framework. The technical assessment revealed that a PV size of 24 kW and a storage capacity of 91 kWh led to the most reliable solution, with a probability of local sufficiency of 95 percent. Furthermore, the environmental assessment showcased a renewable fraction of 94% with a PV size of 26 kW and a storage of 85 kWh. Economically, the analysis identified that a PV size of 12 kW and a storage size of 24 kWh led to the minimum total cost. In contrast, a PV size of 26 kW and a storage size of 85 kWh yielded a total operating savings of $4,801.
dc.description.versionPublisher version
dc.identifier.doi10.61435/ijred.2024.60001
dc.identifier.endpage350
dc.identifier.issn2252-4940
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85188419482
dc.identifier.startpage340
dc.identifier.urihttps://doi.org/10.61435/ijred.2024.60001
dc.identifier.urihttps://hdl.handle.net/10679/10539
dc.identifier.volume13
dc.identifier.wos001186965000004
dc.language.isoen_US
dc.peerreviewedyes
dc.publicationstatusPublished
dc.publisherUniversitas Diponegoro
dc.relation.ispartofInternational Journal of Renewable Energy Development
dc.relation.publicationcategoryInternational Refereed Journal
dc.rightsAttribution-ShareAlike 4.0 International
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-sa/4.0/
dc.subject.keywordsFramework
dc.subject.keywordsSustainability
dc.subject.keywordsEnergy dispatch
dc.subject.keywordsCapacity planning
dc.subject.keywordsNano-grid
dc.titleAn integrated framework for techno-enviro-economic assessment in nanogrids
dc.typearticle
dspace.entity.typePublication
dspace.relatedentity.typePerson
person.identifier.orcid0000-0002-8503-1767
relation.isOrgUnitOfPublication7b58c5c4-dccc-40a3-aaf2-9b209113b763
relation.isOrgUnitOfPublication.latestForDiscovery7b58c5c4-dccc-40a3-aaf2-9b209113b763

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
An integrated framework for techno-enviro-economic assessment in nanogrids.pdf
Size:
1.87 MB
Format:
Adobe Portable Document Format