<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
An integrated framework for techno-enviro-economic assessment in nanogrids

Loading...
Thumbnail Image

Institution Authors

Item type:Person,

Organizational Units

Item type:Organizational Unit,

Research Projects

Advisor

item.page.editor

Editor

Journal Title

Journal ISSN

Volume Title

Publication Status

Published

Journal Issue

Abstract

This paper presents an integrated framework designed for capacity planning of grid -connected nanogrid, a small solar and energy storage system that can provide kilowatt -level services to individual buildings. This framework comprehensively evaluates nanogrid cost-effectiveness, sustainability, and reliability, employing a multi -faceted techno-enviro-economic assessment approach. Traditional nanogrid capacity planning often prioritizes peak load requirements, which may lack optimality owing to occasional peak load occurrences. Conversely, optimizing solely for base load requirements might also fall short of effectiveness, compromising reliability and sustainability objectives. The proposed framework employs a threestep, integrated process for nanogrid (NG) capacity planning. Firstly, the Planner module identifies optimal asset sizing considering a two-day lookahead logic. Then, the Operator module serves as a digital twin for the system, conducting hourly calculations over a short-term horizon. Lastly, the Evaluator module evaluates technical, environmental, and economic metrics for each solution, assessing the effectiveness of asset -sizing decisions. A simulated case study has demonstrated the effectiveness of the proposed framework. The technical assessment revealed that a PV size of 24 kW and a storage capacity of 91 kWh led to the most reliable solution, with a probability of local sufficiency of 95 percent. Furthermore, the environmental assessment showcased a renewable fraction of 94% with a PV size of 26 kW and a storage of 85 kWh. Economically, the analysis identified that a PV size of 12 kW and a storage size of 24 kWh led to the minimum total cost. In contrast, a PV size of 26 kW and a storage size of 85 kWh yielded a total operating savings of $4,801.

Description

Journal or Series

International Journal of Renewable Energy Development

ISSN

2252-4940

ISBN

Keywords

Citation

Publisher

Universitas Diponegoro

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwise noted, this item's license is described as Attribution-ShareAlike 4.0 International

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators