<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Design and analysis of a continuous optoelectronic pulse wave velocity blood pressure sensor with multiple-subject controlled experiments

dc.contributor.authorErkurşun, B.
dc.contributor.authorUçar, Atila
dc.contributor.authorTekin, A.
dc.contributor.ozugradstudentUçar, Atila
dc.date.accessioned2023-06-13T09:46:10Z
dc.date.available2023-06-13T09:46:10Z
dc.date.issued2022-10-16
dc.description.abstractGoal: The main purpose of this study is to perform the pulse wave velocity (PWV) measurements with a new noninvasive optoelectronic continuous-time wearable sensor design and to analyze the quantitative relation between the reference blood pressure (BP) measurement. Methods: PWV was measured at baseline 32 normotensive volunteers, including 15 females and 17 males aged between 23 and 41 years old. The day before the measurements, the volunteers were not allowed to drink alcohol, stay up late or use any medicine that would affect BP. Repeated BP measurements were performed with an average follow-up system at certain times of the day. Results: Equivalent constituents were established after questioning age, height, weight, physical activity levels in daily life, genetic predisposition for blood pressure and diabetic from all volunteers participating in the measurements. Systolic BP (SBP), diastolic BP (DBP), heart rate (HR), pulse pressure (PP), mean arterial pressure (MAP), distance between brachial to radial artery (D), pulse transit time between brachial to radial artery (brPTT) and PWV measurements were all collected to correlate results with the introduced sensor's readings. Following the experimental results, a linear link was found between SBP and PWV when the two groups separated by gender related were examined and the correlation coefficients between them were r: 0.9915 in females and r: 0.9845 in males Conclusion: Measurements taken with the new non-invasive low-power continuous-time sensor design show that the PWV may in the near future be used as a screening tool to identify continuous SBP values in clinical practice. Significance: The new non-invasive design suggests that SBP has the strongest correlation with PWV among a variety of BP parameters.
dc.description.sponsorshipMert Karaca of Microelectronics Lab
dc.identifier.doi10.1016/j.sna.2022.113858
dc.identifier.issn0924-4247
dc.identifier.scopus2-s2.0-85137262665
dc.identifier.urihttp://hdl.handle.net/10679/8383
dc.identifier.urihttps://doi.org/10.1016/j.sna.2022.113858
dc.identifier.volume346
dc.identifier.wos000876300700002
dc.language.isoeng
dc.peerreviewedyes
dc.publicationstatusPublished
dc.publisherElsevier
dc.relation.ispartofSensors and Actuators A: Physical
dc.relation.publicationcategoryInternational Refereed Journal
dc.rightsrestrictedAccess
dc.subject.keywordsBiomedical monitoring
dc.subject.keywordsBlood pressure
dc.subject.keywordsNon-invasive method
dc.subject.keywordsOptical sensors
dc.subject.keywordsPulse pressure
dc.subject.keywordsPulse-wave velocity
dc.titleDesign and analysis of a continuous optoelectronic pulse wave velocity blood pressure sensor with multiple-subject controlled experiments
dc.typearticle
dspace.entity.typePublication

Files

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.45 KB
Format:
Item-specific license agreed upon to submission
Description: