<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Design and analysis of a continuous optoelectronic pulse wave velocity blood pressure sensor with multiple-subject controlled experiments

Loading...
Thumbnail Image

Institution Authors

Organizational Units

Research Projects

Advisor

item.page.editor

Editor

Journal Title

Journal ISSN

Volume Title

Publication Status

Published

Journal Issue

Abstract

Goal: The main purpose of this study is to perform the pulse wave velocity (PWV) measurements with a new noninvasive optoelectronic continuous-time wearable sensor design and to analyze the quantitative relation between the reference blood pressure (BP) measurement. Methods: PWV was measured at baseline 32 normotensive volunteers, including 15 females and 17 males aged between 23 and 41 years old. The day before the measurements, the volunteers were not allowed to drink alcohol, stay up late or use any medicine that would affect BP. Repeated BP measurements were performed with an average follow-up system at certain times of the day. Results: Equivalent constituents were established after questioning age, height, weight, physical activity levels in daily life, genetic predisposition for blood pressure and diabetic from all volunteers participating in the measurements. Systolic BP (SBP), diastolic BP (DBP), heart rate (HR), pulse pressure (PP), mean arterial pressure (MAP), distance between brachial to radial artery (D), pulse transit time between brachial to radial artery (brPTT) and PWV measurements were all collected to correlate results with the introduced sensor's readings. Following the experimental results, a linear link was found between SBP and PWV when the two groups separated by gender related were examined and the correlation coefficients between them were r: 0.9915 in females and r: 0.9845 in males Conclusion: Measurements taken with the new non-invasive low-power continuous-time sensor design show that the PWV may in the near future be used as a screening tool to identify continuous SBP values in clinical practice. Significance: The new non-invasive design suggests that SBP has the strongest correlation with PWV among a variety of BP parameters.

Description

Journal or Series

Sensors and Actuators A: Physical

ISSN

0924-4247

ISBN

Keywords

Citation

Publisher

Elsevier

Endorsement

Review

Supplemented By

Referenced By

Rights and licensing

restrictedAccess

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators