Publication: An experimental study of impinging synthetic jets for heat transfer augmentation
dc.contributor.author | Ghaffari, Omidreza | |
dc.contributor.author | Ikhlaq, Muhammad | |
dc.contributor.author | Arık, Mehmet | |
dc.contributor.department | Mechanical Engineering | |
dc.contributor.ozuauthor | ARIK, Mehmet | |
dc.contributor.ozugradstudent | Ghaffari, Omidreza | |
dc.contributor.ozugradstudent | Ikhlaq, Muhammad | |
dc.date.accessioned | 2016-06-30T12:33:28Z | |
dc.date.available | 2016-06-30T12:33:28Z | |
dc.date.issued | 2015-07 | |
dc.description | Due to copyright restrictions, the access to the full text of this article is only available via subscription. | |
dc.description.abstract | According to recent trends in the field of miniature electronics, the need for compact cooling solutions compatible with very thin profiles and small footprint areas is inevitable. Impinging synthetic jets are recognized as a promising technique for cooling miniature surfaces like laptops, tablets, smart phones and slim TV systems. Effect of jet to cooled surface spacing is crucial in cooling performance as well as predicting Nusselt number for such spacing. An experimental study has been performed to investigate the cooling performance of two different synthetic jets actuated with piezoelectric actuators cooling over a vertical surface. Results showed that a major degradation of heat transfer when jets are close to the surface is occurred. Slot synthetic jets showed a better performance in terms of coefficient of performance (COP) than semi-confined circular jets for small jet to surface spacing. Later, a correlation is proposed for predicting Nu number for a semi-confined circular synthetic jet accounting the effects of Re number (500≤Rej≤1150500≤Rej≤1150), jet-to-surface spacing (H∕D=2H∕D=2 and H∕D=4H∕D=4) and the stroke length (1.75≤L0∕D≤4.751.75≤L0∕D≤4.75 and L0∕H<2.5L0∕H<2.5). It is found that correlation can provide predictions with an R2R2 value of over 98%. | |
dc.identifier.doi | 10.1142/S2010132515500248 | |
dc.identifier.issn | 1229-862X | |
dc.identifier.issue | 3 | |
dc.identifier.scopus | 2-s2.0-84950983243 | |
dc.identifier.uri | http://hdl.handle.net/10679/4157 | |
dc.identifier.uri | https://doi.org/10.1142/S2010132515500248 | |
dc.identifier.volume | 23 | |
dc.language.iso | eng | en_US |
dc.peerreviewed | yes | |
dc.publicationstatus | published | en_US |
dc.publisher | World Scientific Publishing Co | |
dc.relation.ispartof | International Journal of Air-Conditioning and Refrigeration | |
dc.relation.publicationcategory | International Refereed Journal | |
dc.rights | info:eu-repo/semantics/restrictedAccess | |
dc.subject.keywords | Synthetic jet | |
dc.subject.keywords | Small jet to surface spacing | |
dc.subject.keywords | Impinging jet | |
dc.subject.keywords | Heat transfer | |
dc.subject.keywords | Electronics cooling | |
dc.subject.keywords | Cooling efficiency | |
dc.subject.keywords | COP | |
dc.title | An experimental study of impinging synthetic jets for heat transfer augmentation | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
relation.isOrgUnitOfPublication | daa77406-1417-4308-b110-2625bf3b3dd7 | |
relation.isOrgUnitOfPublication.latestForDiscovery | daa77406-1417-4308-b110-2625bf3b3dd7 |