Benchmark study of 2D and 3D VOF simulations of a simplex nozzle using a hybrid RANS-LES approach
(Elsevier, 2022-07-01)
In this study, a simplex nozzle is tested with water for the benchmarking of different flow simulation models. A large scale Plexi-glass transparent nozzle is used to reduce the influence of production tolerances on the ...
Validation and comparison of 2D and 3D numerical simulations of flow in simplex nozzles
(Europe, Institute for Liquid Atomization and Spray Systems, ILASS, 2021-08-31)
Numerical simulations of pressure swirl atomizers are computationally expensive due to transient and multiphase flow behavior. In this study, 2D and 3D VOF simulations are performed for a geomerty which has high swirl ...