Show simple item record

dc.contributor.authorGhaffari, Omidreza
dc.contributor.authorSolovitz, S. A.
dc.contributor.authorIkhlaq, Muhammad
dc.contributor.authorArık, Mehmet
dc.date.accessioned2016-07-29T05:25:56Z
dc.date.available2016-07-29T05:25:56Z
dc.date.issued2016-05-08
dc.identifier.issn1359-4311
dc.identifier.urihttp://hdl.handle.net/10679/4314
dc.identifier.urihttp://www.sciencedirect.com/science/article/pii/S1359431116310080
dc.descriptionDue to copyright restrictions, the access to the full text of this article is only available via subscription.
dc.description.abstractAs compact electronics increase in functionality, new electronics cooling approaches must be more effective, and they must be lower in form factor. In this paper, we investigated the cooling performance of a miniature ultrasonic micro-blower impinging upon a vertical heater. We studied the temperature response at different operating conditions, determining the optimal thermal conditions. We further examined the local flow field using the particle image velocimetry (PIV) technique at the same operating conditions, providing explanations for the heat transfer response in terms of the fluid dynamics. Heat transfer measurements show that the maximum cooling performance occurs at a jet-to-surface spacing ratio of 15 < H/D < 30, and the performance slowly decays when the jet is located further away. The preferred operating frequency of the piezoelectric cooling device occurs at an ultrasonic frequency of over 20 kHz, meaning that this device can function outside the human hearing range. The PIV results demonstrate that the jet profile in the near field deviates significantly from a traditional turbulent free jet. In the far field, it nearly matches the self-similar, fully-developed jet profile. The jet cooling performance is sensitive to the frequency, with the thermal performance dropping by a factor of six when varying by less than 1 kHz from the peak. At the optimal heat transfer condition, the coefficient of performance is measured at approximately three, which is lower than that of some synthetic jets.
dc.description.sponsorshipTÜBİTAK
dc.language.isoengen_US
dc.publisherElsevier
dc.relationinfo:turkey/grantAgreement/TUBITAK/ 112M154
dc.relation.ispartofApplied Thermal Engineering
dc.rightsrestrictedAccess
dc.titleAn investigation into flow and heat transfer of an ultrasonic micro-blower device for electronics cooling applicationsen_US
dc.typeArticleen_US
dc.peerreviewedyes
dc.publicationstatuspublisheden_US
dc.contributor.departmentÖzyeğin University
dc.contributor.authorID(ORCID 0000-0002-9505-281X & YÖK ID 124782) Arık, Mehmet
dc.contributor.ozuauthorArık, Mehmet
dc.identifier.volume106
dc.identifier.startpage881
dc.identifier.endpage889
dc.identifier.wosWOS:000381530600089
dc.identifier.doi10.1016/j.applthermaleng.2016.06.094
dc.subject.keywordsUltrasonic blower
dc.subject.keywordsImpingement
dc.subject.keywordsElectronics cooling
dc.subject.keywordsParticle image velocimetry
dc.subject.keywordsSynthetic jet
dc.subject.keywordsThermal management
dc.identifier.scopusSCOPUS:2-s2.0-84976359260
dc.contributor.ozugradstudentGhaffari, Omidreza
dc.contributor.ozugradstudentIkhlaq, Muhammad
dc.contributor.authorMale3
dc.relation.publicationcategoryArticle - International Refereed Journal - Institutional Academic Staff, PhD Student and Graduate Student


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record