Publication:
Static and dynamic analyses for the exergetic, exergoeconomic and environmental assessment of a high-performance building

dc.contributor.authorAl Doury, Raaid Rashad Jassem
dc.contributor.authorMengüç, Mustafa Pınar
dc.contributor.departmentMechanical Engineering
dc.contributor.ozuauthorMENGÜÇ, Mustafa Pınar
dc.contributor.ozugradstudentAl Doury, Raaid Rashad Jassem
dc.date.accessioned2019-03-25T07:10:08Z
dc.date.available2019-03-25T07:10:08Z
dc.date.issued2018
dc.description.abstractThis paper presents an exergetic, exergoeconomic and environmental assessment of an existing high-performance building using both static and dynamic analyses. The IEA ECBCS framework is adopted for exergy analysis, whereas the SPECO method is used to implement the exergoeconomic analysis. The environmental impact is considered in a quantitative fashion. It is noted that a dynamic analysis using average hourly temperatures is preferred over a static analysis. However, if a simpler static analysis is to be used, an annual average temperature needs to be identified for specific climate zone and building type. For Istanbul, an average temperature of 14°C is recommended.en_US
dc.description.sponsorshipCenter for Energy, Environment and Economy (CEEE) ; European Commission
dc.identifier.doi10.1504/IJEX.2018.095409en_US
dc.identifier.endpage418en_US
dc.identifier.issn1742-8297
dc.identifier.issue3en_US
dc.identifier.scopus2-s2.0-85098826982
dc.identifier.startpage393en_US
dc.identifier.urihttp://hdl.handle.net/10679/6206
dc.identifier.urihttps://doi.org/10.1504/IJEX.2018.095409
dc.identifier.volume27en_US
dc.identifier.wos000449441000005
dc.language.isoengen_US
dc.peerreviewedyesen_US
dc.publicationstatusPublisheden_US
dc.publisherInderscience Enterprises Ltd.en_US
dc.relation.ispartofInternational Journal of Exergy
dc.relation.publicationcategoryInternational Refereed Journal
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subject.keywordsExergyen_US
dc.subject.keywordsExergoeconomicen_US
dc.subject.keywordsEnvironmentalen_US
dc.subject.keywordsStatic analysisen_US
dc.subject.keywordsDynamic analysisen_US
dc.subject.keywordsLow-energy buildingsen_US
dc.subject.keywordsHigh-performance buildingsen_US
dc.titleStatic and dynamic analyses for the exergetic, exergoeconomic and environmental assessment of a high-performance buildingen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isOrgUnitOfPublicationdaa77406-1417-4308-b110-2625bf3b3dd7
relation.isOrgUnitOfPublication.latestForDiscoverydaa77406-1417-4308-b110-2625bf3b3dd7

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.45 KB
Format:
Item-specific license agreed upon to submission
Description: