<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Numerical analysis of the heating zone of a container glass annealing furnace: Effect of circulation fan speed on the heating effectiveness of the furnace

dc.contributor.authorBasol, Altug M.
dc.contributor.authorSisik, Hazar
dc.contributor.authorAsik, Oguzhan
dc.contributor.authorAltun, Gonenc Can
dc.contributor.departmentMechanical Engineering
dc.contributor.ozuauthorBAŞOL, Altuğ Melik
dc.contributor.ozugradstudentAşık, Oğuzhan
dc.contributor.ozugradstudentŞişik, Hazar
dc.contributor.ozugradstudentAltun, Gönenç Can
dc.date.accessioned2025-06-17T07:35:08Z
dc.date.available2025-06-17T07:35:08.595Z
dc.date.issued2024-01-01
dc.description.abstractAnnealing is a heat treatment process commonly carried out in a continuous annealing furnace. While radiative heat transfer is the primary mode of heat transfer in annealing, convective heat transfer also makes a noteworthy contribution. In this numerical study, the effect of the circulation fan flow rate on the heating characteristics of the heating zone of a continuous glass bottle annealing furnace was studied. Heat transfer process is solved by modeling the convection inside the furnace and conduction in the solid glass in separate solvers and by coupling these solvers including radiation in an iterative scheme. The radiation heat transfer between the furnace walls and glass bottles is solved using an in-house developed graphic accelerated Monte Carlo ray tracing algorithm-based model. The glass bottle rows are included as porous zones in the furnace. The flow blockage due to the bottles and convective heat transfer between the bottles and furnace air are calculated using the average flowconditions inside each porous zone. Results clearly show the effect of the circulation fan volumetric flow rate on the shares of the radiative and convective heating mechanisms in the process. Increasing the volumetric flow rate enhances the convective heat transfer rate on the glass which results in lower furnace wall temperatures and it also leads to a considerably more uniform temperature distribution within the glass bottles at the zone outlet. The increased uniformity in the glass temperatures implies a reduction in the soaking zone lengthwhichwould reduce the investment and operational cost of the furnace.
dc.identifier.doi10.1007/978-3-031-67241-5_32
dc.identifier.endpage367
dc.identifier.isbn978-3-031-67240-8
dc.identifier.issn2195-4356
dc.identifier.scopus2-s2.0-85203599595
dc.identifier.startpage357
dc.identifier.urihttps://doi.org/10.1007/978-3-031-67241-5_32
dc.identifier.urihttps://hdl.handle.net/10679/10513
dc.identifier.volume1
dc.identifier.wos001343638600032
dc.language.isoen_US
dc.peerreviewedyes
dc.publicationstatusPublished
dc.publisherSpringer Nature
dc.relation.ispartofAdvances in Computational Heat and Mass Transfer (ICCHMT 2023)
dc.relation.publicationcategoryInternational
dc.rightsrestrictedAccess
dc.subject.keywordsPorous zone
dc.subject.keywordsConvective heat transfer
dc.subject.keywordsRadiative heat transfer
dc.subject.keywordsCirculation fan
dc.subject.keywordsContinuous annealing furnaces
dc.titleNumerical analysis of the heating zone of a container glass annealing furnace: Effect of circulation fan speed on the heating effectiveness of the furnace
dc.typeconferenceObject
dc.type.subtypeConference paper
dspace.entity.typePublication
dspace.relatedentity.typePerson
person.identifier.orcid0000-0002-7289-7246
relation.isOrgUnitOfPublicationdaa77406-1417-4308-b110-2625bf3b3dd7
relation.isOrgUnitOfPublication.latestForDiscoverydaa77406-1417-4308-b110-2625bf3b3dd7

Files