<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Evaluation of NaOH pre-treatment on the corrosion behavior and surface characteristics of hydroxyapatite coated NiTi alloy

dc.contributor.authorŞimşek, Görkem Muttalip
dc.contributor.authorIpekoglu, M.
dc.contributor.authorYapıcı, Güney Güven
dc.contributor.departmentMechanical Engineering
dc.contributor.ozuauthorYAPICI, Güney Güven
dc.contributor.ozugradstudentŞimşek, Görkem Muttalip
dc.date.accessioned2020-11-16T12:17:59Z
dc.date.available2020-11-16T12:17:59Z
dc.date.issued2020-08-02
dc.description.abstractSuccessful short-term implementation of nickel-titanium (NiTi) alloys as implants has been a motivation for the development of long-term applications. However, rendering these as safe implant materials is challenging. The major problem associated with the use of NiTi for in-vivo applications is the potential risk of Ni release from the implant surface due to the corrosive environment of the body. Various methods including surface treatment techniques with acid and alkali solutions and application of biocompatible coatings have been used to overcome these difficulties. In particular, NaOH pre-treatment has been commonly performed for surface activation of the substrate material to enhance the adhesion properties of coatings. The present work investigates the effect of NaOH pre-treatment on the hydroxyapatite (HA) coating and the resulting corrosion behavior of and cell response to HA coated NiTi wires. Microstructural examinations showed that the coating integrity deteriorated with prior NaOH treatment which also increased the corrosion rate as evidenced by potentiodynamic measurements. XPS analysis revealed heightened Ni levels on the sample surfaces and cytotoxicity tests showed decreased cell viability for the samples with pre-treatment. Absence of NaOH pre-treatment led to lower contact angle values pointing to higher biocompatibility.
dc.description.sponsorshipOzyegin University
dc.identifier.doi10.1007/s00339-020-03847-1
dc.identifier.issn0947-8396
dc.identifier.issue8
dc.identifier.scopus2-s2.0-85088877508
dc.identifier.urihttp://hdl.handle.net/10679/7102
dc.identifier.urihttps://doi.org/10.1007/s00339-020-03847-1
dc.identifier.volume126
dc.identifier.wos000559294400001
dc.language.isoeng
dc.peerreviewedyes
dc.publicationstatusPublished
dc.publisherSpringer Nature
dc.relation.ispartofApplied Physics A
dc.relation.publicationcategoryInternational Refereed Journal
dc.rightsopenAccess
dc.subject.keywordsNiTi
dc.subject.keywordsCoating
dc.subject.keywordsHydroxyapatite
dc.subject.keywordsCorrosion
dc.subject.keywordsCell viability
dc.subject.keywordsSurface wettability
dc.titleEvaluation of NaOH pre-treatment on the corrosion behavior and surface characteristics of hydroxyapatite coated NiTi alloy
dc.typearticle
dspace.entity.typePublication
dspace.relatedentity.typePerson
person.identifier.orcid0000-0001-5692-4809
relation.isOrgUnitOfPublicationdaa77406-1417-4308-b110-2625bf3b3dd7
relation.isOrgUnitOfPublication.latestForDiscoverydaa77406-1417-4308-b110-2625bf3b3dd7

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Evaluation of NaOH pre-treatment on the corrosion behavior and surface characteristics of hydroxyapatite coated NiTi alloy.pdf
Size:
2.31 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.45 KB
Format:
Item-specific license agreed upon to submission
Description: