Publication:
Investigation of power distribution on an axial fan

dc.contributor.authorHashim, Hafiz Muhammad
dc.contributor.authorYasa, Y.
dc.contributor.authorDogruoz, M. B.
dc.contributor.authorArık, Mehmet
dc.contributor.authorMese, E.
dc.contributor.departmentMechanical Engineering
dc.contributor.ozuauthorARIK, Mehmet
dc.contributor.ozugradstudentHashim, Hafiz Muhammad
dc.date.accessioned2016-09-18T13:10:04Z
dc.date.available2016-09-18T13:10:04Z
dc.date.issued2016
dc.descriptionDue to copyright restrictions, the access to the full text of this article is only available via subscription.
dc.description.abstractForced convection cooling systems utilize fans which can be axial or radial, small or large in many different configurations. Efficiency of a fan depends on its electrical and mechanical designs as well as the environmental conditions that the fan is exposed to. Typically, the overall efficiency of an axial fan varies between 15 to 40 percent. Power losses may be due to electrical, aerodynamic or mechanical design components. Losses occurring in an axial fan motor have become a critical issue in which high inertial effects, low power, low cost and high efficiency are desired. In order to design an efficient motor, it is important to accurately predict the power losses which are normally dissipated in the form of heat. The present study starts with an investigation of the power losses of an axial fan experimentally and computationally. Moreover, it deals with modeling of mechanical, electrical, thermal and electromagnetic losses which focus especially on an outer rotor brushless DC motor. Reduction of these losses leads to a decrease in the motor temperature and, therefore, has a positive effect on the fan reliability. Expressions for calculating the inverter losses, motor losses and mechanical losses are derived. The power losses obtained are then used as heat sources when evaluating the thermal performance of the motor. By using a two-dimensional model, computational fluid dynamics (CFD) simulations are performed to determine the iron losses across the motor. These results are utilized to determine evaluate the overall efficiency of the system.
dc.description.sponsorshipAselsan ; SSM (undersecretary of Turkish ministry of defense)
dc.identifier.doi10.1109/ITHERM.2016.7517544
dc.identifier.endpage167
dc.identifier.isbn978-146738121-5
dc.identifier.scopus2-s2.0-84983335673
dc.identifier.startpage160
dc.identifier.urihttp://hdl.handle.net/10679/4450
dc.identifier.urihttps://doi.org/10.1109/ITHERM.2016.7517544
dc.identifier.wos000390436000025
dc.language.isoengen_US
dc.peerreviewedyes
dc.publicationstatuspublisheden_US
dc.publisherIEEE
dc.relation.ispartofThermal and Thermomechanical Phenomena in Electronic Systems (ITherm), 2016 15th IEEE Intersociety Conference on
dc.relation.publicationcategoryInternational
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subject.keywordsFan efficiency
dc.subject.keywordsBLDC motor
dc.subject.keywordsCore loss
dc.subject.keywordsFriction loss
dc.subject.keywordsInverter loss
dc.subject.keywordsTorque
dc.subject.keywordsSpeed
dc.titleInvestigation of power distribution on an axial fanen_US