Publication: Effects of turbulence intensity and length scale on the flame location of premixed turbulent combustion in a diffuser combustor
dc.contributor.author | Nazzal, Ibrahim Thamer | |
dc.contributor.author | Ertunç, Özgür | |
dc.contributor.department | Mechanical Engineering | |
dc.contributor.ozuauthor | ERTUNÇ, Özgür | |
dc.contributor.ozugradstudent | Nazzal, Ibrahim Thamer | |
dc.date.accessioned | 2018-01-08T12:38:55Z | |
dc.date.available | 2018-01-08T12:38:55Z | |
dc.date.issued | 2017 | |
dc.description.abstract | This study focused on the dependency of the flame location of a premixed propane-air flame on turbulence intensity and length scale. The flame location was investigated using a diffuser-type combustor to show the response of the flame location to varying turbulence intensities and length scales without changing the mixture velocity, i.e., the thermal power. Combustion simulations were conducted using a coherent flame model within the framework of Reynolds-averaged Navier-Stokes equations under unsteady state conditions. The flame generally moved toward the combustor inlet with increases in turbulence intensity and length scale. The combustion and inlet turbulence caused a flow separation mainly downstream of the flame front. Consequently, the secondary flow structures influenced the flame topology and location. | en_US |
dc.description.sponsorship | TÜBİTAK ; Tikrit University ; Ozyegin University | |
dc.identifier.doi | 10.1299/jtst.2017jtst0029 | en_US |
dc.identifier.endpage | 12 | en_US |
dc.identifier.issn | 1880-5566 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopus | 2-s2.0-85032858520 | |
dc.identifier.startpage | 1 | en_US |
dc.identifier.uri | http://hdl.handle.net/10679/5766 | |
dc.identifier.uri | https://doi.org/10.1299/jtst.2017jtst0029 | |
dc.identifier.volume | 12 | en_US |
dc.identifier.wos | 000422968400014 | |
dc.language.iso | eng | en_US |
dc.peerreviewed | yes | en_US |
dc.publicationstatus | Published | en_US |
dc.publisher | J-STAGE | en_US |
dc.relation.ispartof | Journal of Thermal Science and Technology | |
dc.relation.project | info:eu-repo/grantAgreement/TUBITAK/1001 - Araştırma/114C113 | |
dc.relation.publicationcategory | International Refereed Journal | |
dc.rights | openAccess | |
dc.subject.keywords | Premixed flame | en_US |
dc.subject.keywords | Flame location | en_US |
dc.subject.keywords | Diffuser | en_US |
dc.subject.keywords | Turbulence | en_US |
dc.subject.keywords | Flow separation | en_US |
dc.title | Effects of turbulence intensity and length scale on the flame location of premixed turbulent combustion in a diffuser combustor | en_US |
dc.type | article | en_US |
dspace.entity.type | Publication | |
relation.isOrgUnitOfPublication | daa77406-1417-4308-b110-2625bf3b3dd7 | |
relation.isOrgUnitOfPublication.latestForDiscovery | daa77406-1417-4308-b110-2625bf3b3dd7 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Effects of turbulence intensity and length scale on the flame location of premixed turbulent combustion in a diffuser combustor.pdf
- Size:
- 2.88 MB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
- Name:
- license.txt
- Size:
- 1.45 KB
- Format:
- Item-specific license agreed upon to submission
- Description: