<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Spectral radiation modeling of gas and soot in glass melting furnaces: Evaluation of RC-SLW vs. WSGG model

dc.contributor.authorHalvaşi, Berkay
dc.contributor.authorAltınoluk, T.
dc.contributor.authorBaşol, Altuğ Melik
dc.contributor.authorMengüç, M.Pınar
dc.contributor.authorKaradağ, A.
dc.contributor.departmentMechanical Engineering
dc.contributor.ozuauthorBAŞOL, Altuğ Melik
dc.contributor.ozuauthorMENGÜÇ, Mustafa Pınar
dc.contributor.ozugradstudentHalvaşi, Berkay
dc.date.accessioned2025-11-06T15:42:33Z
dc.date.issued2025-08-01
dc.description.abstractAccurate modeling of thermal radiation is crucial for optimizing heat transfer in glass melting furnaces, as it significantly influences flame behavior within the combustion space. Despite its importance, existing literature lacks comparative studies that solve radiation with spectral accuracy and examine different spectral radiation models in combustion atmospheres. This study addresses this gap by comparing the Rank-Correlated Spectral Line-based Weighted Sum of Gray Gases (RC-SLW) model with gray and non-gray WSGG models. The objective is to investigate the impact of different radiation models on combustion behavior and radiative heat transfer in an industrial-scale glass furnace. The combustion process is modeled using a partially premixed steady diffusion flamelet model, the Moss-Brookes soot mechanism for soot formation and oxidation, and the k-ω SST turbulence model. Spectral radiation effects are assessed by implementing the RC-SLW model in ANSYS Fluent through a user-defined function. The RC-SLW model is validated with a 1-D simulation and compared against the line-by-line model solution. Ten cases are examined. The results show that the gray WSGG model overestimates incident radiation by 10% compared to the RC-SLW model, with this discrepancy increasing to 25% when soot radiation is considered. The gray WSGG model also underestimates crown temperatures by up to 11%, while RC-SLW predictions closely align with experimental data, showing a maximum deviation of 6%. Non-gray WSGG models predict similar incident radiation values as the soot-inclusive RC-SLW model (approximately 40% of total energy), but crown temperatures differ significantly. Soot-only WSGG models show temperature discrepancies of up to 20%. These findings underline the importance of accurate spectral radiation modeling to improve furnace simulation accuracy and optimize heat transfer efficiency. © 2025
dc.description.sponsorshipTÜBİTAK
dc.identifier.doi10.1016/j.tsep.2025.103780
dc.identifier.issn2451-9049
dc.identifier.scopus2-s2.0-105008929031
dc.identifier.urihttps://doi.org/10.1016/j.tsep.2025.103780
dc.identifier.urihttps://hdl.handle.net/10679/11137
dc.identifier.volume64
dc.identifier.wos001521614000002
dc.language.isoen
dc.peerreviewedyes
dc.publicationstatusPublished
dc.publisherElsevier
dc.relation.ispartofThermal Science and Engineering Progress
dc.relation.projectinfo:eu-repo/grantAgreement/TUBITAK/2244 - Sanayi Doktora Programı/118C053
dc.relation.publicationcategoryInternational Refereed Journal
dc.rightsrestrictedAccess
dc.subject.keywordsCombustion
dc.subject.keywordsGlass furnace
dc.subject.keywordsRadiation
dc.subject.keywordsRC-SLW
dc.subject.keywordsWSGG
dc.titleSpectral radiation modeling of gas and soot in glass melting furnaces: Evaluation of RC-SLW vs. WSGG model
dc.typearticle
dspace.entity.typePublication
dspace.relatedentity.typePerson
dspace.relatedentity.typePerson
person.identifier.orcid0000-0002-7289-7246
person.identifier.orcid0000-0001-5483-587X
relation.isOrgUnitOfPublicationdaa77406-1417-4308-b110-2625bf3b3dd7
relation.isOrgUnitOfPublication.latestForDiscoverydaa77406-1417-4308-b110-2625bf3b3dd7

Files