<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Seismic performance assessment of an existing anchored and a self-anchored liquid storage tank in high seismic regions

dc.contributor.authorErkmen, Bulent
dc.contributor.departmentCivil Engineering
dc.contributor.ozuauthorERKMEN, Bülent
dc.date.accessioned2025-06-17T22:14:00Z
dc.date.available2025-06-17T22:14:01.365Z
dc.date.issued2024-05-15
dc.description.abstractThis study presents seismic performance of two existing at-grade industrial liquid-storage tanks located in the Eastern part of Marmara region, which is a high seismic region in Turkey. The first tank is self-anchored (unanchored) and has been in service for 44 years, while the other tank is mechanically anchored to a reinforced concrete foundation and has been in service for 50 years. Tanks seismic performance is evaluated using tank time-history earthquake analyses with recorded ground motions scaled for each tank site. The liquid content was included in the developed model using provisions of API 650. Tanks base uplift, sliding on the foundation, tank shell and bottom plate damage, and demand on tank anchorage were determined. The results shows that self-anchored tank has base plate uplift and sliding that are larger than the allowable limits while the mechanically anchored tank has acceptable seismic performance with potential seismic damage of tank anchorage system. The findings of this study contribute valuable insight into the seismic performance of existing liquid storage tanks in the region under new seismic regulations and increased seismic loads than those used for their design.
dc.description.sponsorshipTÜBİTAK
dc.description.versionPublisher version
dc.identifier.doi10.1007/s10518-024-01932-x
dc.identifier.endpage4217
dc.identifier.issn1570-761X
dc.identifier.issue8
dc.identifier.scopus2-s2.0-85192892386
dc.identifier.startpage4197
dc.identifier.urihttps://doi.org/10.1007/s10518-024-01932-x
dc.identifier.urihttps://hdl.handle.net/10679/10530
dc.identifier.volume22
dc.identifier.wos001223448400002
dc.language.isoen_US
dc.peerreviewedyes
dc.publicationstatusPublished
dc.publisherSpringer Nature
dc.relation.ispartofBulletin of Earthquake Engineering
dc.relation.publicationcategoryInternational Refereed Journal
dc.rightsAttribution 4.0 International
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.keywordsFluid-structure interaction
dc.subject.keywordsTank base uplift
dc.subject.keywordsLiquid-storage tank
dc.subject.keywordsMechanically anchored tank
dc.subject.keywordsSelf-anchored tank
dc.titleSeismic performance assessment of an existing anchored and a self-anchored liquid storage tank in high seismic regions
dc.typearticle
dspace.entity.typePublication
dspace.relatedentity.typePerson
person.identifier.orcid0000-0002-3980-3770
relation.isOrgUnitOfPublicationaf7d5a6d-1e33-48a1-94e9-8ec45f2d8c85
relation.isOrgUnitOfPublication.latestForDiscoveryaf7d5a6d-1e33-48a1-94e9-8ec45f2d8c85

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Seismic performance assessment of an existing anchored and a self-anchored liquid storage tank in high seismic regions.pdf
Size:
3.96 MB
Format:
Adobe Portable Document Format