Show simple item record

dc.contributor.authorGüngör, Ö.
dc.contributor.authorHassine, Chedia Ben Ali
dc.contributor.authorBurç, M.
dc.contributor.authorKöytepe, S.
dc.contributor.authorDuran, S. T.
dc.date.accessioned2023-08-16T05:55:33Z
dc.date.available2023-08-16T05:55:33Z
dc.date.issued2022
dc.identifier.issn2008-4226en_US
dc.identifier.urihttp://hdl.handle.net/10679/8692
dc.identifier.urihttps://www.abechem.com/article_251273.html
dc.description.abstractIn this study, the metoprolol (MTP), which is a beta-blocker class molecule used in hypertension treatment, was determined by modifying the glassy carbon electrode (GCE) with a molecular imprinting technique. Firstly, p-toluene sulfonic acid (PTSA) and aniline (AN) were co-electropolymerized in the presence of MTP as a template molecule on GCE and MTP contained poly(aniline-co-p-toluene sulfonic acid) (p(AN-co-PTSA)) film was obtained. Then, the template metoprolol molecule was desorbed from the conductive p(AN-co-PTSA) film structure on the GCE surface using hydrochloric acid. Obtained molecularly imprinted electrodes were used to determine MTP by the square wave voltammetry (SWV) method. The modified electrodes obtained showed a correlation coefficient (R²) of 0.9995 in the 40-1500 µM MTP concentration range. The limit of detection (LOD) and the limit of quantification (LOQ) of the p(AN-co-PTSA) film modified MTP electrodes were 37.9 µM and 126.3 µM, respectively. A standard deviation of 1.33% was observed for the first three replicates with the same modified electrode. For the time reproduced electrodes, stable reproducibility was achieved between the first electrode result and the tenth electrode result. For the modified MTP electrode, the relative standard deviation (RSD%) value was calculated to be 2.53%. As result, the molecularly imprinted electrodes prepared with p(AN-co-PTSA) film have low response time, high reproducibility, good stability, and high selectivity for the determination of MTP.en_US
dc.description.sponsorshipİnönü University
dc.language.isoengen_US
dc.publisherCenter of Excellence in Electrochemistryen_US
dc.relation.ispartofAnalytical and Bioanalytical Electrochemistry
dc.rightsrestrictedAccess
dc.titlePreparation of molecularly imprinted metoprolol sensor from poly(aniline-co-p-toluene sulfonic acid)en_US
dc.typeArticleen_US
dc.peerreviewedyesen_US
dc.publicationstatusPublisheden_US
dc.contributor.departmentÖzyeğin University
dc.identifier.volume14en_US
dc.identifier.issue3en_US
dc.identifier.startpage290en_US
dc.identifier.endpage302en_US
dc.identifier.wosWOS:000782847500002
dc.subject.keywordsMetoprololen_US
dc.subject.keywordsElectropolymerizationen_US
dc.subject.keywordsMolecularly imprinted electrodeen_US
dc.subject.keywordsSensoren_US
dc.subject.keywordsVoltammetryen_US
dc.identifier.scopusSCOPUS:2-s2.0-85128511222
dc.contributor.ozugradstudentHassine, Chedia Ben Ali
dc.relation.publicationcategoryArticle - International Refereed Journal - Institutional Graduate Student


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


Share this page