Show simple item record

dc.contributor.authorErkmen, Bülent
dc.date.accessioned2024-04-18T05:23:36Z
dc.date.available2024-04-18T05:23:36Z
dc.date.issued2017
dc.identifier.urihttp://hdl.handle.net/10679/9332
dc.identifier.urihttps://www.eccomasproceedia.org/conferences/thematic-conferences/compdyn-2017/5523
dc.description.abstractSeismic performance of two unanchored liquid-storage tanks with tank diameter of 24.5 m and 36 m and operating liquid height of 12.2 m and 20.0 m, respectively were investigated using Coupled Eulerian-Lagrangian (CEL) and mechanical spring-mass analogy nonlinear finite element computational methods. The CEL approach includes the effects of higher modes of liquid vibration (sloshing), liquid breaking effects, and liquid-structure interaction during seismic loading. The modern seismic design provisions for liquid-storage tanks, on the other hand, are based on a mechanical spring-mass analogy. This approach neglects the higher vibration modes for the sloshing water, liquid-structure interaction, and effects of tank base uplift on seismic performance. For the tanks, base uplift histories were computed with both modeling approaches through nonlinear time history analysis performed using five recorded earthquake acceleration data. The uplift histories were compared to evaluate the adequacy of code seismic design provisions for unanchored tanks, and to determine whether the mechanical spring-mass analogy can be used to predict seismic performance of unanchored tanks. Analysis results show that the traditional mechanical spring-mass analogy, which is the basis for the current seismic design provisions, does not capture tank uplift history and its effects on dynamic loads. This approach underpredicts the total numbers of tank uplifts during seismic loading. The maximum tank base uplift computed using mechanical spring-mass analogy had an average error between 22% and 58 % for each tank. The results show that there is a need to developed a modify version of the traditional mechanical spring-mass analogy to be used for predicting seismic performance of unanchored liquid-storage tanks.en_US
dc.language.isoengen_US
dc.publisherNational Technical University of Athensen_US
dc.relation.ispartofCOMPDYN 2017 - Proceedings of the 6th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering
dc.rightsrestrictedAccess
dc.titleEvaluation of code provisions for seismic performance of unachored liquid storage tanksen_US
dc.typeConference paperen_US
dc.publicationstatusPublisheden_US
dc.contributor.departmentÖzyeğin University
dc.contributor.authorID(ORCID 0000-0002-3980-3770 & YÖK ID 181924) Erkmen, Bülent
dc.contributor.ozuauthorErkmen, Bülent
dc.identifier.volume1en_US
dc.identifier.startpage1700en_US
dc.identifier.endpage1710en_US
dc.identifier.doi10.7712/120117.5523.18579en_US
dc.subject.keywordsBase upliften_US
dc.subject.keywordsLiquid storage tanksen_US
dc.subject.keywordsSeismic performanceen_US
dc.subject.keywordsUnanchored tanksen_US
dc.identifier.scopusSCOPUS:2-s2.0-85042504180
dc.relation.publicationcategoryConference Paper - International - Institutional Academic Staff


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


Share this page