Al Doury, Raaid Rashad JassemMengüç, Mustafa Pınar2019-03-252019-03-2520181742-8297http://hdl.handle.net/10679/6206https://doi.org/10.1504/IJEX.2018.095409This paper presents an exergetic, exergoeconomic and environmental assessment of an existing high-performance building using both static and dynamic analyses. The IEA ECBCS framework is adopted for exergy analysis, whereas the SPECO method is used to implement the exergoeconomic analysis. The environmental impact is considered in a quantitative fashion. It is noted that a dynamic analysis using average hourly temperatures is preferred over a static analysis. However, if a simpler static analysis is to be used, an annual average temperature needs to be identified for specific climate zone and building type. For Istanbul, an average temperature of 14°C is recommended.enginfo:eu-repo/semantics/restrictedAccessStatic and dynamic analyses for the exergetic, exergoeconomic and environmental assessment of a high-performance buildingArticle27339341800044944100000510.1504/IJEX.2018.095409ExergyExergoeconomicEnvironmentalStatic analysisDynamic analysisLow-energy buildingsHigh-performance buildings2-s2.0-85098826982