Publication:
Completing the missing link in building design process: Enhancing post-occupancy evaluation method for effective feedback for building performance

dc.contributor.authorGöçer, Özgür
dc.contributor.authorHua, Y.
dc.contributor.authorGöçer, K.
dc.contributor.departmentArchitecture
dc.contributor.ozuauthorGÖÇER, Özgür
dc.date.accessioned2015-10-26T13:01:35Z
dc.date.available2015-10-26T13:01:35Z
dc.date.issued2015-07
dc.descriptionDue to copyright restrictions, the access to the full text of this article is only available via subscription.
dc.description.abstractThis paper provides a review of the improvements in the evaluation of building performance and introduces a new method for post-occupancy evaluation (POE) to complete the missing link in the building design process. Existing studies were reviewed to understand the possible reasons for the missing link of “building performance feedback”. The intention of this paper is to set out a new vision for how future post-occupancy evaluation can close the building performance feedback loop to better inform building design. The spatial mapping method adopted extends the use of building information modeling (BIM), which has shown great potential for the future of the Architecture, Engineering and Construction (AEC) industry, and uses geographical information systems (GIS), which is a powerful tool for analyzing and visualizing relationships between geographical units and their data. This study explores how to establish a communication platform for different stakeholders in order to engage them in the collaborative effort of continuous building performance improvement by using the results of POE embedded into BIM. In this paper, the experiences of a POE study of a LEED® Platinum building and a historical building on a university campus are reported as examples to illustrate the proposed new method.en_US
dc.description.sponsorshipTÜBİTAK ; Jacobs Technion-Cornell Institute
dc.identifier.doi10.1016/j.buildenv.2015.02.011
dc.identifier.endpage27
dc.identifier.issn0360-1323
dc.identifier.scopus2-s2.0-84923884844
dc.identifier.startpage14
dc.identifier.urihttp://hdl.handle.net/10679/972
dc.identifier.urihttps://doi.org/10.1016/j.buildenv.2015.02.011
dc.identifier.volume89
dc.identifier.wos000364440600002
dc.language.isoengen_US
dc.peerreviewedyesen_US
dc.publicationstatuspublisheden_US
dc.publisherElsevieren_US
dc.relationinfo:eu-repo/grantAgreement/TUBITAK/1001 - Araştırmaen_US
dc.relation.ispartofBuilding and Environmenten_US
dc.relation.publicationcategoryInternational Refereed Journal
dc.rightsrestrictedAccess
dc.subject.keywordsBuilding performanceen_US
dc.subject.keywordsFeedbacken_US
dc.subject.keywordsPost-occupancy evaluationen_US
dc.subject.keywordsStakeholdersen_US
dc.subject.keywordsBIMen_US
dc.subject.keywordsGISen_US
dc.titleCompleting the missing link in building design process: Enhancing post-occupancy evaluation method for effective feedback for building performanceen_US
dc.typearticleen_US
dspace.entity.typePublication
relation.isOrgUnitOfPublication90b26182-c9cb-45ba-8961-d43ebaafde63
relation.isOrgUnitOfPublication.latestForDiscovery90b26182-c9cb-45ba-8961-d43ebaafde63

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections